TRIPP-LITE UPS 30kVa SVT30KX 3-Phase 380/400/415V 30kVA 9kW On-Line Double-Conversion UPS SmartOnline SVTX Series , Tower, Extended Run, SNMP Option 30000va
- Provides fully regulated sine wave AC output for critical telecom, network, security, financial, corporate and light industrial applications
- +/-1% output voltage regulation in online and battery modes
- High 0.9 power factor offers 20kVA/18kW output capacity, allowing for more connected devices
- Selectable 380/400/417V output voltage
- Wide input voltage windowimizes battery use and prolongs battery life
- Supports half load for 17 and full load for 4 .
- Zero transfer time suitable for advanced network applications
- Expandable runtime with optional external battery packs, such as Tripp Lite?s BP240V175
- Restarts automatically after lengthy power outages
- Produces output power with less than 2% THD to keep connected equipment functioning at its peak
- Low <6% THDi input rating and advanced IGBT rectifier enables 1:1 Generator Sizing, eliating costly oversizing requirements for generators, breakers and cables
- Connect up to 3 units in parallel configuration for increased capacity
- Increases system reliability
- Allows maintenance without removing power from attached loads
- Operates at efficiency levels as high as 98.8% when input line conditions are favorable
- Slot for WEBCARDLX network interface or RELAYCARDSV relay card for remote monitoring and control options
- Optional WEBCARDLXwith the latest version of PowerAlert Device Manager firmwareprovides enhanced remote management capabilities
- PADM20 and PowerAlert Element Managerform a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations
- DB9 and EPO ports offer local monitoring and shutdown options
- Reduced-size black tower case saves valuable floor space
- Matching external battery cabinets enable extended runtime options
OVERVIEW
INPUT
| Rated input current (Maximum Load) | 34.4A |
| Nominal Input Voltage(s) Supported | 220/380V 3-PH Wye; 230/400V 3-PH Wye; 240/415V 3-PH Wye |
| Nominal Input Voltage Description | 3-Phase Wye, 4 wire plus ground (L1, L2, L3, N, G) |
| UPS Input Connection Type | Hardwire |
| Input Circuit Breakers | 63A (3 pole) |
| Input Phase | 3-Phase |
| Power Factor (Input) | .99PF (100% load) |
| THDi | <6% (100% load) |
OUTPUT
| Output Volt Amp Capacity (VA) | 20000 |
| Output Capacity (kVA) | 20 |
| Output Watt Capacity (Watts) | 18000 |
| Output kW Capacity (kW) | 18 |
| Output Capacity Details | Supports up to 100% load continuously in double conversion mode; Supports 100-110% load for 10 minutes, 110 to 130% load for 1 minute and greater than 130% for 1 second before switching to bypass mode; Inverter mode is automatically restored as load levels are reduced to 70% or less; Configuration options support up to 3 SVT20KX systems wired in parallel for increased capacity. |
| Power Factor | 0.9 |
| Crest Factor | 3:1 |
| Frequency Compatibility | 50 / 60 Hz |
| Frequency Compatibility Details | Automatic frequency selection |
| Output Voltage Regulation (Line Mode) | +/- 1% |
| Output Voltage Regulation (Economy Line Mode) | +/-11V of selected nominal output voltage (220V: 209-231V; 230V: 219-241; 240V: 229-251V) |
| Output Voltage Regulation (Battery Mode) | +/- 2% |
| Output AC Waveform (AC Mode) | Pure Sine wave |
| Output AC Waveform (Battery Mode) | Pure Sine wave |
| Nominal Output Voltage(s) Supported | 220/380V 3-PH Wye; 230/400V 3-PH Wye; 240/415V 3-PH Wye |
| Output Receptacles | Hardwire |
| Individually Controllable Load Banks | No |
BATTERY
| Full Load Runtime (min.) | 4 min (18kW) |
| Half Load Runtime (min.) | 11 min. (9kW) |
| Expandable Battery Runtime | Supports extended runtime optional external battery packs |
| Expandable Runtime | Yes |
| External Battery Pack Compatibility | BP240V135 |
| DC System Voltage (VDC) | 240 |
| Battery Recharge Rate (Included Batteries) | 4 hours to 90% (Internal batteries) |
VOLTAGE REGULATION
| Voltage Regulation Description | Online, double-conversion power conditioning maintains output within 1% of the selected nominal voltage in online mode |
| Overvoltage Correction | Corrects overvoltage conditions to 520V (50% load) and 478V (100% load) |
| Undervoltage Correction | Corrects brownout conditions to 110V (50% load) / 305V (100% load) |
USER INTERFACE, ALERTS & CONTROLS
| Front Panel LCD Display | LCD DISPLAY: offers a variety of graphical, text and numeric information to indicate a wide range of UPS operation and fault / warning conditions, including current operating mode, alarm status, load level, battery charge, input / output voltage & frequency, estimated runtime and more (see user manual for a detailed listing) |
| Switches | ON / ENTER BUTTON: turns the UPS on and confirms a selection from the settings menu; OFF / ESC BUTTON: turns off the UPS and returns to the previous item in the settings menu; TEST / UP BUTTON: initiates UPS self-test operation and advances to the next item in the settings menu; MUTE / DOWN BUTTON: silences the audible alarm and advances to the previous item in the settings menu; Press TEST/UP & MUTE/DOWN buttons simultaneously for 1 second to enter or exit the settings menu (See user manual for detailed information) |
| Audible Alarm | Alarms warn users of a variety of operational conditions: BYPASS MODE (beeps every 2 seconds), BATTERY MODE (beeps every 4 seconds), FAULT MODE (beeps continuously), OVERLOAD (beeps twice per second), OTHER WARNINGS (beeps once per second), FAULT (beeps continuously); All alarms can be silenced, except OVERLOAD & OTHER WARNINGS conditions |
| LED Indicators | 4 LEDs report BYPASS / LINE / BATTERY / FAULT modes |
PHYSICAL
| Primary Form Factor | Tower |
| Cooling Method | Fans |
| Installation Form Factors Supported with Included Accessories | Tower |
| Primary UPS Depth (mm) | 813 |
| Primary UPS Height (mm) | 861 |
| Primary UPS Width (mm) | 249 |
| Shipping Dimensions (hwd / cm) | 106.02 x 38.00 x 92.00 |
| Shipping Weight (kg) | 193.68 |
| UPS Housing Material | Steel |
| UPS Power Module Dimensions (Height x Width x Depth, mm) | 862 x 250 x 813 |
| UPS Power Module Dimensions (hwd, cm) | 86.11 x 24.89 x 81.28 |
| UPS Power Module Weight (kg) | 177.81 |
ENVIRONMENTAL
| Operating Temperature Range | 0 to +40C (32-104F) |
| Storage Temperature Range | 0 to +35C (32 to 95F) with battery; -15 to 60C (5 to +140F) without battery |
| Relative Humidity | 5 to 95%, non-condensing |
| AC Mode BTU / Hr. (Full Load) | 6079 |
| Operating Elevation (ft.) | < 3000ft (Capacity de-rates by 1% for every 330ft over 3000) |
| Audible Noise | <65dBA front side 1M |
| Operating Elevation (m) | < 1000m (Capacity de-rates by 1% for every 100m over 1000) |
COMMUNICATIONS
| Network Management Cards | WEBCARDLX ; MODBUSCARDSV ; RELAYCARDSV |
| Network Monitoring Port Description | Card accessory slot also supports network interface and relay card options |
| Communications Cable | DB9 cabling included |
| Communications Interface | DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface |
LINE / BATTERY TRANSFER
| Transfer Time | Zero transfer time in ONLINE MODE (0ms); ECONOMY MODE: 7ms from AC to Battery mode / 0.6ms from Battery to AC mode |
| Low Voltage Transfer to Battery Power (Setpoint) | 110V (50% load) / 305V (100% load) |
| High Voltage Transfer to Battery Power (Setpoint) | 520V (50% load) / 478V (100% load) |
FEATURES & SPECIFICATIONS
| Grounding Lug | Yes |
| Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported |
| High Availability UPS Features | Automatic inverter bypass; Manual bypass switch; Auto Probe Monitoring (requires WEBCARDLX); Zero transfer time; On-Line/Double-Conversion |
| Green Energy-Saving Features | High efficiency economy mode operation |
STANDARDS & COMPLIANCE
| UPS Certifications | CE |
| Certification Details | EN 62040-1-1 (Safety); EN 62040-2 (Category C3) |

iPhone
Samsung Phones
Smart Watch
Google Pixel Phones
Sony Phones
itel Mobile Phone
Monitor Screen
Television All Brands
Washing Machines
Air conditions
Micro Oven
Weighing Machine KG weight Measure Scale
Water Dispenser
DISHWASHER MACHINE
Sandwich Maker
Deep Fryer
Rice Cooker
Coffee Maker & Electric Kettle



Reviews
There are no reviews yet.