Description
TRIPP-LITE UPS 10kVa SVT10KX 3-Phase 380/400/415V 10kVA 9kW On-Line Double-Conversion UPS 10000va
Specifications
OVERVIEW
UPC Code | 037332192455 |
UPS Type | On-Line |
INPUT
Input Phase | 3-Phase |
Rated input current (Maximum Load) | 17.4A |
Nominal Input Voltage(s) Supported | 220/380V 3-PH Wye; 230/400V 3-PH Wye; 240/415V 3-PH Wye |
Nominal Input Voltage Description | 3-Phase Wye, 4 wire plus ground (L1, L2, L3, N, G) |
UPS Input Connection Type | Hardwire |
Power Factor (Input) | .99PF (100% load) |
THDi | <6% |
OUTPUT
Output Capacity (VA) | 10000 |
Output Capacity (kVA) | 10 |
Output Capacity (Watts) | 9000 |
Output Capacity (kW) | 9 |
Output Capacity Details | Supports up to 100% load continuously in double conversion mode; Supports 100-110% load for 10 minutes, 110 to 130% load for 1 minute and greater than 130% for 1 second before switching to bypass mode; Inverter mode is automatically restored as load levels are reduced to 70% or less |
Power Factor | 0.9 |
Crest Factor | 3:1 |
Frequency Compatibility | 50 / 60 Hz |
Frequency Compatibility Details | Automatic frequency selection |
Output Voltage Regulation (Line Mode) | +/- 1% |
Output Voltage Regulation (Economy Line Mode) | +/-11V of selected nominal output voltage (220V: 209-231V; 230V: 219-241; 240V: 229-251V) |
Output Voltage Regulation (Battery Mode) | +/- 1% |
Output AC Waveform (AC Mode) | Pure Sine wave |
Output AC Waveform (Battery Mode) | Pure Sine wave |
Nominal Output Voltage(s) Supported | 220/380V 3-PH Wye; 230/400V 3-PH Wye; 240/415V 3-PH Wye |
Output Receptacles | Hardwire |
BATTERY
Runtime Full Load (min.) | 3.8 min. (9kW) |
Runtime Half Load (min.) | 10.5 min. (4500W) |
Expandable Runtime | Yes |
External Battery Pack Compatibility | Â BP240V135 |
DC System Voltage (VDC) | 240 |
Battery Recharge Rate (Included Batteries) | 4 hours to 90% (Internal batteries) |
VOLTAGE REGULATION
Voltage Regulation Description | Online, double-conversion power conditioning maintains output within 1% of the selected nominal voltage in online mode |
Overvoltage Correction | Corrects overvoltage conditions to 520V (50% load) and 478V (100% load) |
Undervoltage Correction | Corrects brownout conditions to 110V (50% load) / 305V (100% load) |
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display | LCD DISPLAY: offers a variety of graphical, text and numeric information to indicate a wide range of UPS operation and fault / warning conditions, including current operating mode, alarm status, load level, battery charge, input / output voltage & frequency, estimated runtime and more (see user manual for a detailed listing) |
Switches | ON / ENTER BUTTON: turns the UPS on and confirms a selection from the settings menu; OFF / ESC BUTTON: turns off the UPS and returns to the previous item in the settings menu; TEST / UP BUTTON: initiates UPS self-test operation and advances to the next item in the settings menu; MUTE / DOWN BUTTON: silences the audible alarm and advances to the previous item in the settings menu; Press TEST/UP & MUTE/DOWN buttons simultaneously for 1 second to enter or exit the settings menu (See user manual for detailed information) |
Audible Alarm | Alarms warn users of a variety of operational conditions: BYPASS MODE (beeps every 2 seconds), BATTERY MODE (beeps every 4 seconds), FAULT MODE (beeps continuously), OVERLOAD (beeps twice per second), OTHER WARNINGS (beeps once per second), FAULT (beeps continuously); All alarms can be silenced, except OVERLOAD & OTHER WARNINGS conditions |
LED Indicators | 4 LEDs report BYPASS / LINE / BATTERY / FAULT modes |
PHYSICAL
Primary Form Factor | Tower |
Cooling Method | Fans |
Installation Form Factors Supported with Included Accessories | Tower |
Primary UPS Depth (mm) | 813 |
Primary UPS Height (mm) | 861 |
Primary UPS Width (mm) | 249 |
Shipping Dimensions (hwd / in.) | 41.74 x 14.96 x 36.22 |
Shipping Weight (lbs.) | 295.00 |
UPS Housing Material | Steel |
UPS Power Module Dimensions (Height x Width x Depth, mm) | 862 x 250 x 813 |
UPS Power Module Dimensions (hwd, in.) | 33.9 x 9.8 x 32 |
UPS Power Module Weight (kg) | 117.93 |
UPS Power Module Weight (lbs.) | 260 |
Unit Weight (lbs.) | 260.15 |
ENVIRONMENTAL
Operating Temperature Range | 32° to 104°F (0° to 40°C) |
Storage Temperature Range | 32° to 95°F (0° to 35°C) with battery; 5° to 140°F (-15° to 60°C) without battery |
Relative Humidity | 5 to 95%, non-condensing |
AC Mode BTU / Hr. (Full Load) | 3415 |
Operating Elevation (ft.) | < 3000ft (Capacity de-rates by 1% for every 330ft over 3000) |
Audible Noise | <65dBA front side 1M |
Operating Elevation (m) | < 1000m (Capacity de-rates by 1% for every 100m over 1000) |
COMMUNICATIONS
Network Management Cards | WEBCARDLX; Â WEBCARDLXEÂ ; Â MODBUSCARDSVÂ ; RELAYCARDSV |
Network Monitoring Port Description | Card accessory slot also supports network interface and relay card options |
Communications Cable | DB9 cabling included |
Communications Interface | DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface |
LINE / BATTERY TRANSFER
Transfer Time | Zero transfer time in ONLINE MODE (0ms); ECONOMY MODE: 7ms from AC to Battery mode / 0.6ms from Battery to AC mode |
Low Voltage Transfer to Battery Power (Setpoint) | 110V (50% load) / 305V (100% load) |
High Voltage Transfer to Battery Power (Setpoint) | 520V (50% load) / 478V (100% load) |
FEATURES & SPECIFICATIONS
Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported |
High Availability UPS Features | Automatic inverter bypass; Manual bypass switch; Auto Probe Monitoring (requires WEBCARDLXE); Zero transfer time; On-Line/Double-Conversion |
Green Energy-Saving Features | High efficiency economy mode operation |
Grounding Details | Yes |
APPLICATIONS
UPS Applications | Mission Critical Applications |
STANDARDS & COMPLIANCE
Product Certifications | IEC/EN 62040 |
Product Compliance | RoHS; CE (Europe) |
Reviews